Installation manualSimrad ES70Fish nding echo sounderTECHNOLOGY FOR SUSTAINABLE FISHERIESwww.simrad.com

Page 2

SimradES70Grounding...188Cableconnections...

Page 3

SimradES70NoteThecurrentthatcanbedrawnfromthisopencollectorcircuitryislimitedto100mAFigure19Differentialinput39k68k68,1k+5Vdc100k(+)(-)C C(CD010010C)

Page 4 - Supportinformation

InterfacesandintegrationGPTAuxiliaryconnectorTheES70GeneralPurposeTransceiver(GPT)boardcontainsa25-pinfemaleDeltaconnectorhandlingvariousexternalinter

Page 5 - Tableofcontents

SimradES70•Supplyvoltages(output)–Pin5:+12Vdc,max100mA(Groundonpin18)–Pin6:-12Vdc,max100mA(Groundonpin19)–Pin7:+5Vdc,max200mA(Groundonpin20)•Transmits

Page 6

DrawingleDrawingleThischaptercontainsrelevantdrawingsrelatedtotheelectricalandphysicalinstallationoftheES70Fishndingechosounder.NoteThemechanicaldr

Page 7

SimradES70GPTOutlinedimensionsPage1Forpanelmounting,usecountersunkheadscrews:M5machinescrews,4.8mmplatescrewsor5mmwoodscrews.Vedpane

Page 8

DrawinglePage2CD010215BPage2of2820-201035Rev .CNote:Allmeasurementsareinmm.Thedrawingisnotinscale.AvailableforserviceAdkomstforvedl

Page 9

SimradES70GPTPowersupplyoutlinedimensionsPage16512514019013011025,619,315CD010215CPage1of2305274Rev .ANote:Allmeasurementsareinmm.Thedrawing

Page 10 - 343522/A

DrawinglePage2625430190130CD010215CPage2of2305274Rev .ANote:Allmeasurementsareinmm.Thedrawingisnotinscale.343522/A105

Page 11 - Aboutthismanual

SimradES70Marinecomputeroutlinedimensions8080224264207 1958686184268219CD010218APage1of1Rev.ANote:Allmeasurementsareinmm.Thedrawingisnotin

Page 12

DrawingleGPTTransducerplugconnectionRubbersleeveRubbersleeveRetainingringContactbodyPlugfasteningringUpperplugcaseBottomcapandcableclampWas

Page 13 - Systemoverview

AboutthismanualAboutthismanualThepurposeofthismanualThepurposeofthisinstallationmanualistoprovidethedescriptionsandproceduresrequiredtoinstalltheSimra

Page 14 - Mainunits

SimradES70TechnicalspecicationsThischapterliststhemaintechnicalspecications.NoteWereservetherighttoaltertechnicalspecicationswithoutpriornotice.Rel

Page 15 - Simpliedsystemdiagrams

Technicalspecications•Bottomdetector:Softwaretrackingalgorithm,adjustableminimumandmaximumdepthInterfacespecicationsNumerousexternalinterfacesarepro

Page 16 - Generalsupplyconditions

SimradES70Physicalandenvironmentalspecications•Connectors:–Transducer:12-pinfemaleAmphenol,ShellMS3102A-24,Insert24-19S–AUI:15-pinfemaleDelta(seebelo

Page 17 - Compassdeviation

TechnicalspecicationsColourdisplayspecicationsCommercialdisplayTheES70FishndingechosoundermaybesuppliedwithoneofseveralLCDdisplays,andseveralsizesa

Page 18 - Drydocking

SimradES70•Physicaldimensions:–Depth:195mm–Width:268mm–Height:80mm•Environmentalspecications:–Operatingtemperatures:-10to+50°C–Storagetemperatures:-2

Page 19 - Installationprocedures

TransducerInstallationTransducerInstallationThepurposeofthischapteristoprovidegenericdescriptionsandillustrationsallowingthereadertounderstandthebasic

Page 20 - Conguration

SimradES701Theupperwaterlayersoftheseacontainamyriadofsmallairbubblescreatedbythebreakingwaves.Inheavyseastheupper5to10metresmaybelledwithair,andtheh

Page 21 - Echosoundertransducer

TransducerInstallationFigure21BoundarywaterlayerATurbulentowBLaminarowCAirbubblesinthewaterFurthermore,airbubblesintheseawaterarepresseddownbelowthe

Page 22

SimradES70rule.Certainthrusterdesignscombinedwithitsphysicallocationonthehullmaystilloffersuitabletransducerlocationsnearthethruster.Ifyouareindoubt,c

Page 23 - ES70MarineComputer

TransducerInstallationIfthevesselhullhasabulbousbow,thismaywellbeagoodtransducerlocation,butalsoheremustbetakenintoconsiderationtheowpatternoftheaera

Page 24 - Software

SimradES70SimradES70ThepurposeofthischapteristoprovideanoveralldescriptionoftheES70Fishndingechosoundersystemanditsmainfeatures.Topics•Importantonpag

Page 25

SimradES70ExternalmountingofstreamlinedtransducerCertaintransducershaveastreamlinedhousing,andthesearedesignedforinstallationoutsidethehull.Thesetrans

Page 26

TransducerInstallationExample:StreamlinedtransduceronsteelhullAfairing(A),madebytheshipyard,isplacedbetweenthetransducerandthehull.Itisrequiredinorder

Page 27

SimradES70Example:StreamlinedtransduceronwoodenorpolyesterhullAfairing(A),madebytheshipyard,isplacedbetweenthetransducerandthehull.Itisrequiredinorder

Page 28 - ES70Cablelayout

TransducerInstallationExample:StreamlinedtransduceronhullwithatbottomIfthevessel’shullisatyoudonotneedafairing.Thetransduceristhenbebolteddirectlyto

Page 29 - Cableplan

SimradES70SmoothsurfaceisimportantMountingscrewsorboltsmustnotbeextrudingfromthetransducerortheareaimmediatelyaroundit.Makesurethatthesurfaceofthetran

Page 30 - ES70Cableplan

TransducerInstallationExample:LargecirculartransducerTheillustrationbelowshowsatypicaltransducerblisterdesignedforalargetransducer.Notethatduetothephy

Page 31

SimradES70Example:SmallcirculartransducerTheillustrationbelowshowsatypicaltransducerblisterdesignedforasmalltransducer.Thesameblisterdesignprinciplesa

Page 32

TransducerInstallationExample:MediumsizedcirculartransducerwithoutclampingringTheillustrationbelowshowsatransducerblisterdesignedforamediumsizedtransd

Page 33 - Listofcables

SimradES70Theinterioroftheblistermustbelledwithseawater.Usedrainageholesinthebottomandanairoutletonthetop.Thewaterpressurebehindthetransducerwillthen

Page 34 - EK60/C11Serialinterfaceline

TransducerInstallationObservethehorizontalandverticaldistances(CandD)betweenthekeelandthetransducerblister.Onamediumsizedvessel,thehorizontaldistance(

Page 35

SimradES70IfsomethingbreaksdownIfyoubelievethatsomethinghasbrokendown,contactyourlocaldealer.Hewillbeabletoassist.WhenyouswitchofftheechosounderYoumus

Page 36

SimradES70UseahorizontalsupportbaronlargetransducersWestronglyrecommendthatlargetransducersarettedwithahorizontalsupportbar.Thepurposeofthissupportba

Page 37 - Connectoridentications

TransducerInstallationUsemountingandclampingringswheneverprovidedCirculartransducersmaybeprovidedwithmountingandclampingrings,orwithdrawingstoallowfor

Page 38

SimradES70Example:FlushmountinginasteeltankTransducermountinginasteeltankisshowninthegurebelow.Figure33FlushmountinginasteeltankASteeltankBWaterCDrai

Page 39 - Transducerconnections

TransducerInstallationExample:AcousticwindowThetransducershowninthegurebelowismountedinsidethetankbehindastrongacousticwindowwhichcouldbemadeofpolyca

Page 40

SimradES70SmoothsurfaceisimportantMountingscrewsorboltsmustnotbeextrudingfromthetransducerortheareaimmediatelyaroundit.Makesurethatthesurfaceofthetran

Page 41 - Figure14Transducerconnector

TransducerInstallationTransducermountedonadropkeelTheuseofadropkeelwiththepurposeofstabilisingthevesseliswellknown.Adropkeelisalsoasuperiorplatformfor

Page 42 - Cabledrawings

SimradES70RetractabletransducerHullunitsallowingthetransducertobeloweredandhoistedarecommonlyusedforhorizontallookingsonars.Whennotinuse,thetransducer

Page 43 - GenericRS-232Serialline

TransducerInstallationUsemountingandclampingringswheneverprovidedCirculartransducersmaybeprovidedwithmountingandclampingrings,orwithdrawingstoallowfor

Page 44

SimradES70MediumandlargetransducersTheillustrationbelowshowstheinstallationprincipleofamediumorlargetransducers.Notethataclampingringisnotrequired,ast

Page 45 - RS-232asexternaltrigger

TransducerInstallationDualtransducerarrangementTheillustrationbelowshowsatypicalthroughthehullinstallationofsmallandlargecirculartransducersonatowedbo

Page 46 - Sonarsynchronisation

SimradES70MainunitsThebasicES70Fishndingechosounderconsistsof:•Display•Computer(TheES70MarineComputermaybeprovided)•OneormoreGeneralPurposeTransceive

Page 47 - Commercialpowersupply

SimradES70AboutcableglandsAsteelcableglandisnormallyusedonprofessionalvesselswithsteelhulls.Abronzecableglandcanbedeliveredasanoptionforvesselswithwoo

Page 48 - Vesselground

TransducerInstallationCableglandforsteelhullsThiscableglandkitisdesignedforsteelvessels.Itmustbeweldedtothehullplates.(CD17008A)ø35ø65AABCCDEFASteelco

Page 49 - GPTexternalpower

SimradES70CableglandforwoodenandGRPhullsAbronzecableglandkitisavailableforwoodenandglass-reinforcedplastic(GRP)vessels.(CD17008B)ABBBCCCDEFAPackingnip

Page 50 - ACmains(IEC60320)

TransducerInstallationCableglandsforsmallhullsThiscableglandsmadeofplasticisdesignedforthosesmallervesselsthatdonotneedtobeclassied.(CD17008C)AAJBCDG

Page 51 - RJ45Ethernet,straight

SimradES70TransducercablesplicingIfyouneedtocutorlengthenthetransducercable,youmustspliceitcorrectly.Thecablebetweenthejunctionboxandthetransceivermus

Page 52 - RJ45Ethernet,crossover

TransducerInstallationSteelconduitsqualitiesandshieldingThesteelconduitmustbeunbrokenandwatertightfromthetransducertoabovethewaterline.Fromthere,theca

Page 53 - VGA/SVGADisplay

SimradES70SpecialrulesforacousticwindowsArctictankshaveacousticwindowsmadeofpolycarbonate.Th e s e m u s t n e i t h e r b ep a i n t e d n o r c l e

Page 54

TransducerInstallationInternationalMarineCoatingsAddress:World-wideofcesWebsite:ww w . i n t e r n a t i o n a l - m a r i n e . c o m .1Intersleekti

Page 55 - Parallelprinter

SimradES70Figure39Example,internalandexternalthreadsA B C21(CD017020B)AEmuge’ ssaw-toothproleuptopitchP≤0.7mmBEmuge’ ssaw-toothproleuptopitchP≥0.7mm

Page 56 - DVI–IDisplay

TransducerInstallationDrawingstandardWheneverself-lockingthreadsarerequired,thisisshownonthetechnicaldrawing.Inthecaseoftappingthroughholes,thearrowat

Page 57 - Seriallineadapter

SimradES70AtwistedpairEthernetcableconnectstheGeneralPurposeTransceiver(GPT)tothecomputer.ThedistancebetweenthecomputerandtheGeneralPurposeTransceiver

Page 58 - GPTremoteon/off

SimradES70NoteInthecaseoftappingthroughholesitisimportantthattheproleoftheEmugeself-lockthreadsisinthecorrectdirectioncomparedwiththeenteringdirectio

Page 59

SimradtransducersSimradtransducersThischapterpresentsalistofallthecurrentSimradtransducers.Foreachtransducer,informationisprovidedtoestablish:•thetran

Page 60 - GPTtrigger/synchronisation

SimradES70•Ordernumber,transducercable:642-022491•GPTconnection:12-16/60transduceronpage72Simrad18–11•Typeandfrequency:Singlebeam,18kHz•Openingangle:1

Page 61 - GPT Battery

Simradtransducers•Typicalapplications:Fishndingandhydrographicechosounders•Ordernumber,transducer:KSV-203635•Ordernumber,transducercable:642-016604•G

Page 62 - ITIserialline

SimradES70Simrad50-18•Typeandfrequency:Singlebeam,50kHz•Openingangle:18°•Typicalapplications:Hydrographicechosounders•Ordernumber,transducer:KSV-08260

Page 63 - PI44/54serialline

Simradtransducers•GPTconnection:Singlebeam/normalpowertransduceronpage64Simrad200-7C•Typeandfrequency:Singlebeam,200kHz•Openingangle:7°•Typicalapplica

Page 64 - PI30/32serialline

SimradES70•Ordernumber,transducer:KSV-109178•Ordernumber,transducercable:642-016604•GPTconnection:Singlebeam/normalpowertransduceronpage64Simrad200-35

Page 65 - Sonarserialline

SimradtransducersSimradES38-10•Typeandfrequency:Splitbeam,38kHz•Openingangle:10°•Typicalapplications:Fishndingechosounders•Ordernumber,transducer:KSV

Page 66

SimradES70•Ordernumber,transducercable:Shipyardsupply•GPTconnection:Deepwater,splitbeamtransduceronpage73SimradES70-11•Typeandfrequency:Splitbeam,70kH

Page 67

Simradtransducers•Typicalapplications:Fishndingandscienticechosounders•Ordernumber,transducer:KSV-204580•Ordernumber,transducercable:642-078215•GPTc

Page 68

SimradES70Figure4SystemdiagramwithtwoGeneralPurposeTransceiversADisplayUnitBProcessorUnit(computer)CGeneralPurposeTransceiver(GPT)DTransducer(s)EEther

Page 69 - Splitbeamtransducer

SimradES70•Typeandfrequency:Splitbeam,120kHz•Openingangle:2,5x9,5°•Typicalapplications:Scienticechosounders•Ordernumber,transducer:KSV-111154•Ordernu

Page 70

SimradtransducersSimradES200-7CD•Typeandfrequency:Splitbeam,200kHz•Openingangle:7°•Typicalapplications:Scienticechosounders,Towedbody•Ordernumber,tra

Page 71

SimradES70TelegramformatsThischapterdescribestheexternalNMEAandproprietarytelegraminterfacessupportedbytheES70Fishndingechosounder.Thechapterincludes

Page 72 - ES38–10transducer

TelegramformatsAbouttheNMEAtelegramformatTheSimradES70cansendandreceiveinformationtoandfromseveraldifferentperipherals.Alltransmissionstakeplaceastele

Page 73

SimradES70Format$--DBS,x.x,f,y.y,M,z.z,F*hh<CR><LF>Formatdescription1––=talkeridentier2DBS=telegramidentier3x.x,f=depthbelowsurfaceinfee

Page 74 - 12-16/60transducer

Telegramformats2DPT=telegramidentier3x.x=waterdepth,inmeters,relativetothetransducer4y.y=offset,inmeters,fromthetransducer5z.z=maximumrangescaleinuse

Page 75

SimradES703llll.ll,a=latitudenorth/south,positionindegrees,minutesandhundredths.CharactersN(North)orS(South)identiesthebearing.4yyyyy.yy,a=longitudee

Page 76 - 50/200CombiCtransducer

TelegramformatsHDTHeading,trueThistelegramisusedtotransferheadinginformationfromagyro.Format$--HDT,x.x,T*hh<CR><LF>Formatdescription1––=ta

Page 77 - 38/200CombiCtransducer

SimradES70Formatdescription1––=talkeridentier2VHW=telegramidentier3x.x,T=heading,degreestrue4x.x,M=heading,degreesmagnetic5x.x,N=speedrelativetowate

Page 78 - Softwareinstallation

TelegramformatsProprietarytelegramsandformatsThefollowingproprietarySimradtelegramsaresupportedbytheES70Fishndingechosounder.Topics•SimradEK500Deptho

Page 79 - HowtoupgradetheES70software

SimradES70Receipt,unpackingandstorageUponacceptingshipmentoftheequipment,theshipyardand/orthedealershouldensurethatthedeliveryiscompleteandinspecteach

Page 80 - HowtoremovetheES70software

SimradES70floatSs[4];longTransducerNumber[4];floatAthwartShips;};Ethernetformatdescription1Header#=canbeD1,D2orD3forchannels1,2or3.2Separator=“,”3Time

Page 81 - Connectingthetransceiver

Telegramformats3Youcandenehowrollisassumedtobemeasured,eitherwithrespecttothehorizontalplane(theHippy120orTSSconvention),ortotheplanetiltedbythegiven

Page 82 - Setupprocedure

SimradES70givenpitchangle(i.e.asarotationanglearoundthepitchtiltedforwardpointingx-axis).Thelatterconvention(calledTate-BryantinthePOS/MVdocumentation

Page 83 - Howtoinstallafrequencychannel

TelegramformatsFormatdescription1II=talkeridentier(mandatory)2HFB=telegramidentier3x.x,M=distancefromheadropetofootrope,meters4y.y,M=distancefromfoo

Page 84 - HowtomodifyanIPaddress

SimradES7012qual=quality:•0=Noconnectionbetweenthesensorandthereceiver•1=Oneortwotelemetrypulsesarelost,currentvalueispredicted•2=Thecurrentdatavaluei

Page 85

Telegramformats9z.z=relativebiomassdensityinm²/nmi²(NASC)(sA)NASCmeansNauticalAreaScatteringCoefcient.Thisistheformat(sAm²/nmi²)weprovidethebiomassda

Page 86 - Interfacesandintegration

SimradES70•H=Headingaidedmodeandstabledata.Thesensoroperateswithexternalinputofheadingdata.•h=Headingaidedmodebutunstabledata.Thesensoroperateswithext

Page 87 - Externalinterfaces

TelegramformatsTopics•Atlasdepthtelegramonpage175AtlasdepthtelegramThisproprietaryAtlastelegramcontainsthecurrentdepthfromtwochannels.FormatDyxxxxx.xx

Page 88

SimradES70APPENDIXA—GENERALSAFETYRULESTheSimradES70Fishndingechosoundersystemoperateson230Vac50/60Hz.WARNINGThisvoltagemaybelethal!Thefollowingsafety

Page 89

AppendixBEquipmenthandlingAPPENDIXB—EQUIPMENTHANDLINGThissectionprovidesthebasicrulesfortransportation,storageandhandlingofunits.Inthiscontext,aunitma

Page 90

SimradES70NoisesourcesThevessel’shull,rudder(s)andpropeller(s)shouldbethoroughlyinspectedindrydockpriortoinstallation.Roughnessbelowthewater-linedefor

Page 91

SimradES70Ensurethatallavailableliftinglugsareused.Ensuretheunitremainsundercontrolduringtheoperationtoavoiddamagetotheunit,equipmentorpersonnel.Heavy

Page 92

AppendixBEquipmenthandling13Iftheunitcontainsnormalbatteries,thesemayhavebeendisconnected/isolatedbeforetheunitwaspacked.Thesemustonlybereconnectedbef

Page 93 - NMEASentencetouse

SimradES701Checkthecartonbeforeopeningittoensureitshowsnosignsofdropping,immersioninwaterorothermishandling.Ifthecartonshowssignsofsuchdamage,refertot

Page 94

AppendixBEquipmenthandlingUnpackingtransducersTransducersmaybesuppliedmountedtoahullunit(ifany),orpackedseparately.Cratesarenormallyidentiedbytheorde

Page 95 - Howtosetupthedepthoutput

SimradES70CleaningcabinetsIfacabinethasbeenexposedtosaltatmospherewhileitwasinuse,itmustbethoroughlycleanedbothinternallyandexternallytopreventcorrosi

Page 96

AppendixBEquipmenthandlingInternalbatteriesIftheunitcontainsbatteries,thesemaydischargeslowlyduringstorage.Iftheunitistobestoredforanextendedperiod,di

Page 97 - ES70Externaltriggering

SimradES70Mustnotbetransportedorstoredintemperaturesbelow-5degreesCelsius.Otherunitscannormallybestoredintemperaturesbetween-30°Cand+70°C,refertothesy

Page 98

AppendixBEquipmenthandlingUnpackingonboardthevesselWhenyouareworkingonboardavessel,an“approvedconductiveservicemat”isoftenfaraway.Asyoustillneedtounpa

Page 99 - (CD010010A)

SimradES702Theservicepersonnelinvolvedmustwearawristbandindirectcontactwiththeskin,connectedtotheservicemat.3Printedcircuitboardsmustbeplacedonthecond

Page 100 - (CD010010C)

AppendixCBasiccablerequirementsAPPENDIXC—BASICCABLEREQUIREMENTSThischapterprovidesgeneralinformationrelatedtotheinstallationofsystemcables.Topics•Cabl

Page 101 - GPTAuxiliaryconnector

InstallationproceduresInstallationproceduresThischapterprovidesthebasicinformationrequiredtoinstallthephysicalunits.NotePhysicalinstallationofcommerci

Page 102

SimradES70•Toallowforfutureexpansionofthesystem,allcablesshouldbeallocatedspareconductorpairs.Also,spacewithinthevesselshouldbesetasidefortheinstallat

Page 103 - Drawingle

AppendixCBasiccablerequirementsanddesignedtoensureagoodgroundconnection.Theglandsusedmustbermlyattachedto,andingoodelectricalcontactwith,ametalstruct

Page 104 - GPTOutlinedimensions

SimradES70Index12kHztransducersSimrad12-16/60,149120khztransducersSimrad120-25,152SimradES120-2,5x10,157SimradES120-4x10,158SimradES120-7,156SimradES1

Page 105 - Monteringseksempler

Indexgrounding,188identication,189physicalprotection,188radiofrequencyinterference,188terminations,189trays,187Cabletraysrequirements,187Cablingdrawi

Page 106 - SimradES70

SimradES70Insidethehull,132Mountingring,123,125,135Streamlinedblister,123,125Exportdata,84Externalmountinstallation,118Externalmountingathull,121poly

Page 107

IndexFlushmounting,128Hullunit,134Insidethehull,131Retractable,134Steeltank,128Towedbody,134Integration,84Interfaceexternal,84InterfacesetupITI,87Inte

Page 108

SimradES70Propellernoise,115Proprietarytelegramspecications,167,174ProtectionagainstESD,185temperature,183Protrudingobjects,114PSIMDHBtelegram,172PSI

Page 109 - GPTTransducerplugconnection

Indexshielding,143why,142Steelhullcablegland,139externalmounting,119Steeltankushmounting,128waterlled,129StopbitNMEA0183standard,85Storageequipment(

Page 110 - Technicalspecications

SimradES70TransducerES38–10,155TransducerES38B,155TransducerES38DD,155TransducerES70-11,156TransducerES70-7C,156Transducerfacecleaning,143painting,143

Page 113 - Colourdisplayspecications

SimradES70•Videocablefromcomputertodisplaymonitor.•Connectthepointingdevice(mouseortrackball)•Connectthekeyboard.5MounttheGeneralPurposeTransceiver(GP

Page 114

ISBN-13:978-82-8066-117-3©2010KongsbergMaritimeAS

Page 116

Simrad ES70 Fish nding echo sounderInstallation manualSimrad ES70 Fish nding echo sounderInstallation manualSimrad ES70 Fish nding echo sounderInst

Page 117

Installationprocedures•Keyboard[3]•Pointingdevice(mouseortrackball)•Ethernetswitch(ifthesystemcomprisesmorethanonetransceiver)•Software•Printer(option

Page 118

SimradES70Figure5GeneralPurposeTransceiver(GPT)TheGeneralPurposeTransceiver(GPT)isasmallself-containedunitcontainingitsownpowersupply.Itoperateson+12V

Page 119 - Howtoinstallthetransducer

InstallationproceduresRelatedtopics•GeneralPurposeTransceiver(GPT)specicationsonpage109•GeneralPurposeTransceiver(GPT)installationonpage22ES70MarineC

Page 120 - (CD17010C)

SimradES70•Interfaces:–OneEthernetinterfacetocommunicatewiththetransceiver–OneEthernetinterfacetocommunicatewithship’slocalareanetwork(ifrequired)–One

Page 121

InstallationproceduresFigure7GeneralPurposeTransceiver(GPT)Preparations•Twobracketsandfourpanheadscrewsareenclosed.Thesidewallsoftheuniteachholdsixscr

Page 122

SimradES70ES70MarineComputerinstallationTheES70MarineComputerisanindustrialcomputer.Itissmall,rugged,andcontainsnomovingparts.Thismeansthatfans,harddi

Page 123

InstallationproceduresInstallationprocedureToensurecorrectoperation,tickoffeveryitemwhentheactionhasbeencarriedout.1Installthecolourdisplayasdescribed

Page 124

SimradES70ES70CablelayoutThischapterdescribestheinstallationrequirementsfortheES70Fishndingechosoundersystemcables.NoteAllelectronicinstallationsandc

Page 125 - (CD017010A)

ES70CablelayoutCableplanDuetoitsmodulardesign,theSimradES70Fishndingechosoundersystemcanbesetupinavarietyofcongurationstosuitindividualneedsforopera

Page 126 - (CD017010B)

SimradES70InstallationmanualThismanualprovidesyouwiththebasicinformationrequiredtoinstalltheSimradES70Fishndingechosounder.Formoredetailedinformation

Page 127 - Commonguidelines

SimradES70ES70CableplanFigure9Cableplan,topsideC06C05C04C11/C12/C13/C14C15/C16/C17/C18C07C08C10 C09 C20C03 C01C02BADEC(CD010227-001)ADispl

Page 128

ES70CablelayoutFigure10Cableplan,singleGeneralPurposeTransceiver(GPT)C10C20 C21C24C23C26C25SIMRADGPT(CD010227-002)ABD CEAGeneralPurposeTransceiver(GPT

Page 129 - Smoothsurfaceisimportant

SimradES70Figure11Cableplan,dualGeneralPurposeTransceiver(GPT)SIMRAD GPTSIMRAD GPTC10C10 C10C20C20/21C20/21C21C25C25C26C26C23C23C24C24(CD010227-003)AA

Page 130

ES70CablelayoutListofcablesThelistbelowspecieseachcableusedontheechosoundersystem.Referencesaremadetothelocationofconnector(s),detailedcabledrawingsa

Page 131

SimradES70C8EK60/C08ComputertogroundWhenapplicable,thiscablemustbeprovidedbytheinstallationshipyard.Itisastandardcommercialgroundcable.•V esselgroundo

Page 132 - Transducerwithacousticwindow

ES70Cablelayout•Sonarseriallineonpage63•Seriallineadapteronpage55C12EK60/C12Serialinterfaceline(sameasC11)C13EK60/C13Serialinterfaceline(sameasC11)C14

Page 133 - (CD017012B)

SimradES70synchronizationsignalTrigInmustbeconnectedtoa l l ofthem.Thecable(s)mustbesuppliedbytheinstallationshipyard.IftheES70systemissynchronisedusi

Page 134 - Example:Mountinginsidethehull

ES70CablelayoutConnectoridenticationsThissectionprovidesthenecessaryillustrationstoidentifythevariousconnectorsandterminalboardsontheechosounderunits

Page 135 - (CD017012D)

SimradES70Figure13GPTAuxiliaryconnector(CD010009B)13121110090807060504030201TRIGIN+TRIGOUT+ALARMOUTEVENT INLOGINNOT USED+5Vdc(MAX200MA)-12Vdc

Page 136 - Towedbodyinstallation

ES70CablelayoutTransducerconnectionsTransducertypesTheechosoundercanbeusedwithalargevarietyoftransducers.ThelargetransducerconnectorontheGeneralPurpos

Page 137 - Smalltransducer

DocumenthistoryDocumentnumber:343522/Rev.A/ISBN-13:978-82-8066-117-3Rev.A03.02.2010Firstversion.Copyright©2010KongsbergMaritimeASTheinformationcontain

Page 138 - Mediumandlargetransducers

SimradES70•Singlebeam/highpowertransduceronpage65•Dualbeam(wideornarrow)transduceronpage66•Splitbeamtransduceronpage67•Splitbeamtransducertosinglebeam

Page 139 - Dualtransducerarrangement

ES70CablelayoutGPTconnectorEnsurethatthetransducerconnectoriswiredcorrectlyregardinginnerandouterscreen.Figure14Transducerconnector343522/A39

Page 140 - Aboutcableglands

SimradES70CabledrawingsThischapterprovidesdetailscabledrawingsofferingcablespecicationsandterminationinformation.Cablespecicationdrawings•GenericRS-

Page 141 - Cableglandforsteelhulls

ES70CablelayoutGenericRS-232SeriallineThiscableholdsamultipurposeserialline.Itprovidesinterfacewithanyperipheralunit.Oneendofthecableconnectstotheloca

Page 142 - (CD17008B)

SimradES70GenericRS-232SeriallineThiscablecomprisesamultipurposeserialline.Itprovidesinterfacewithanyperipheralunit.Oneendofthecableconnectstothelocal

Page 143 - Cableglandsforsmallhulls

ES70CablelayoutRS-232asexternaltriggerThiscablecomprisesanRS-232seriallineappliedasanexternaltrigger.Itprovidesinterfacewithanyperipheralunitthatrequi

Page 144 - Steelconduit

SimradES70SonarsynchronisationThiscableconnectstheechosoundertotheInterfaceUnitonaSimradsonar.Thecableallowsforexternalsynchronisationofthesonartransm

Page 145 - Rulesfortransducerhandling

ES70CablelayoutCommercialpowersupplyThisisastandardcommercialpowersupply.Theinputisnormally115and/or230Vac,whiletheoutputvoltageandpowercapacityissetu

Page 146 - Rulesfortransducermaintenance

SimradES70VesselgroundThiscableisusedtoconnectasystemunittotheship’sground.Notethatthiscablemustbeasshortaspossible.Cablespecications•Conductors:1x6m

Page 147 - Usingself-lockingtaps

ES70CablelayoutGPTexternalpowerInordertosuppresselectricnoise,certainechosoundercongurationsrequireanexternalpowersupply.Thispowersupplyisthenusedins

Page 148 - (CD017020B)

InstallationmanualTableofcontentsABOUTTHISMANUAL...9SIMRADES70...

Page 149 - Tapsandgauges

SimradES70ACmains(IEC60320)Thisisacommercial230V acpowercableformainspower.OneendisttedwithanIECplug,theotherwithastandardEuropeanmainsplug.Thisisast

Page 150 - Supplierandmanufacturer

ES70CablelayoutRJ45Ethernet,straightThiscableisusedtoprovidestandardEthernetconnections.Notethatvariouscategoriesexists.Normally,CAT-5EandCAT-6cablesa

Page 151 - Simradtransducers

SimradES70RJ45Ethernet,crossoverThiscableisusedtoprovidestandardethernetconnections.Notethatvariouscategoriesexists.Normally,Cat.5andCat.6cablesareuse

Page 152

ES70CablelayoutVGA/SVGADisplayThisisastandardVGAandSVGAvideocable.Oneendisnormallyconnectedtothedisplay,whiletheotherendisterminatedinastandardD-conne

Page 153

SimradES70USBJustaboutanycomputerthatyoubuytodaycomeswithoneormoreUniversalSerialBus(USB)connectorsontheback.Theseconnectorsletyouattacheverythingfrom

Page 154

ES70CablelayoutParallelprinterThisisastandard“Centronics”parallelprintercable.Itisprovidedready-madewithprinters,andalsoobtainablefromcommercialretail

Page 155

SimradES70DVI–IDisplayThiscableisastandardDVI-Icable.Itisnormallyprovidedwiththecolourdisplay.FormoreinformationabouttheDVIsignals,seeht t p : / / e n

Page 156 - Allsplit–beamtransducers

ES70CablelayoutSeriallineadapterThisisacommercialadapter.ItallowsyoutoconnectfourRS-232seriallinestoacommonsocketonthecomputer.W510Rev.ASeriallinead

Page 157

SimradES70GPTremoteon/offThiscableisusedtoconnectaremoteon/offswitchtotheGeneralPurposeTransceiver(GPT).Theswitchcanbelocatedinaseparateboxmanufacture

Page 158

ES70CablelayoutRemotepoweron/offwhenmultipletransceiversareusedWhenmultipletransceiversareused,twowiringoptionsareavailable:•Youcanswitchalltransceive

Page 159

SimradES70Cabledrawings...40GenericRS-232Seriallin

Page 160

SimradES70GPTtrigger/synchronisationThiscableisusedtoconnecttheGeneralPurposeTransceiver(GPT)toanexternalsystemforsynchronisationpurposes.Itconnectsto

Page 161

ES70CablelayoutGPTbatteryThiscableisusedtoconnectabatterytotheGeneralPurposeTransceiver(GPT).Redplugandredsocketisnormallyusedforpositive(+).Blackplug

Page 162 - Telegramformats

SimradES70ITIseriallineThiscableisusedtoprovideatwo-waycommunicationtoaSimradITITrawlsystem.Cablespecications•Conductors:9x2x0.5mm²•Screen:Screenedtw

Page 163 - DBSDepthbelowsurface

ES70CablelayoutPI44/54seriallineThiscableisusedtoprovideatwo-waycommunicationtoaSimradPI44orPI54catchmonitoringsystem.Cablespecications•Conductors:9x

Page 164 - DPTDepth

SimradES70PI30/32seriallineThiscableisusedtoprovideatwo-waycommunicationtoaSimradPI30orPI32catchmonitoringsystem.Cablespecications•Conductors:9x2x0.5

Page 165

ES70CablelayoutSonarseriallineThiscableisusedtoprovideatwo-waycommunicationtoasonarsystemusinganInterfaceUnit.Cablespecications•Conductors:9x2x0.5mm²

Page 166 - HDMHeading,magnetic

SimradES70Singlebeam/normalpowertransducerThisistheterminationofthetransducercablefromasinglefrequency,singlebeamtransducertothetransducersocketontheG

Page 167 - VHWWaterspeedandheading

ES70CablelayoutSinglebeam/highpowertransducerThisistheterminationofthetransducercablefromasinglefrequency,singlebeamtransducertothetransducersocketont

Page 168 - VLWDualground/waterdistance

SimradES70Dualbeam(wideornarrow)transducerThisistheterminationofthetransducercablefromasinglefrequency,dualbeamtransducertothetransducersocketontheGen

Page 169 - SimradEK500Depth

ES70CablelayoutSplitbeamtransducerThisistheterminationofthetransducercablefromasinglefrequency,splitbeamtransducertothetransducersocketontheGeneralPur

Page 170 - SimradEMAttitude1000

InstallationmanualWiringprocedure,onetransceiver...79Wiringprocedure,twoormoretransceiver

Page 171 - SimradEMAttitude3000

SimradES70SplitbeamtransducertosinglebeamtransceiverThisistheterminationofthetransducercablefromasinglefrequency,splitbeamtransducer-wiredasasinglebea

Page 172 - DBSDepthoftrawlbelowsurface

ES70CablelayoutDualfrequency,singlebeamtransducerThisistheterminationofthetransducercablefromadualfrequency,singlebeamtransducertothesocketontheGenera

Page 173 - PSIMP .DPISensordata

SimradES70ES38–10transducerThisistheterminationofthetransducercablefromtheES38–10split-beamtransducertothetransducersocketontheES60andEK60GeneralPurpo

Page 174

ES70CablelayoutSinglebeamtransducertosplitbeamtransceiverThisistheterminationofthetransducercablefromasinglefrequency,singlebeamtransducertothesocketo

Page 175 - Sounder/TSS1Motionprotocol

SimradES7012-16/60transducerThisistheterminationofthetransducercablefromthe12–16/60singleordualbeamtransducertothetransducersocketontheGeneralPurposeT

Page 176 - SimradATSAnnotation

ES70CablelayoutDeepwater ,splitbeamtransducerThisistheterminationofthetransducercablefromadeepwatertransducer.Thistransducerisdesignedtobeusedtowedbod

Page 177 - Atlasdepthtelegram

SimradES7050/200CombiCtransducerThisistheterminationofthetransducercablefromtheSimrad50/200CombiCtransducer.ThetransducercableisterminatedinaMini-Con-

Page 178 - APPENDIXA—GENERALSAFETYRULES

ES70Cablelayout38/200CombiCtransducerThisistheterminationofthetransducercablefromtheSimrad38/200CombiCtransducer.ThetransducercableisterminatedinaMini

Page 179 - Transportation

SimradES70SoftwareinstallationThischapterdescribeshowtoinstalltheES70software,howtoupgrade,howtoobtainasoftwarelicense,andnallyhowtoremovethesoftware

Page 180

SoftwareinstallationThischapterisprovidedintheES70OperatormanualandES70Referencemanual.HowtoobtaintheES70licenseTheES70requiresavalidlicensetooperate.

Page 181 - Unpacking

SimradES70TRANSDUCERINSTALLATION...113Wheretomountthetransducer...

Page 182 - Unpackingmechanicalunits

SimradES701Observetheprocedureforsoftwareinstallation.Unlessyouhavemadeanyhardwarechangesonyourcomputer,theexistingsoftwarelicensewillbeused.Howtoremo

Page 183 - Storageafteruse

ConnectingthetransceiverConnectingthetransceiverThischapterexplainshowtoconnecttheES70computertothetransceiver,andhowtosetupthefrequencychannels.Eacht

Page 184 - Mechanicalunits

SimradES703Connecta“straight”cablefromthecomputer’sEthernetsockettothe“uplink”socketontheEthernetswitch.→RJ45Ethernet,straightonpage494Connect“straigh

Page 185 - Temperatureprotection

ConnectingthetransceiverHowtoinstallafrequencychannel1ClicktheSetupiconundertheMainmenutoopentheSetupsub-menu.2ClickInstallationtoopentheInstallations

Page 186

SimradES70Onthesub-menu,clickTransceiverInstallationtoopentheTransceiverInstallationdialog.3Observethatcurrentfrequencychannelsarelistedinthedialog.Ea

Page 187 - Electro-StaticDischarge(ESD)

Connectingthetransceiver6Settthetransducer(s)toNone,andclickApply.7ClickChangeIPAddresstoopentheIPAddressdialog.NoteIfyouhavetwoEthernetcablesconnecte

Page 188

SimradES70InterfacesandintegrationTheSimradES70computerprovidesoneormoremultipurposeserialandEthernetportsforexternalinterfaces.Whichinterfacestouse,a

Page 189 - Cabletrays

InterfacesandintegrationNMEATheNationalMarineElectronicsAssociation(NMEA)hasdenedcommunicationstandardsformaritimeelectronicequipment,andtheES70echos

Page 190 - Grounding

SimradES70HowtosetuptheEthernetoutputinterfaceTheES70cancommunicatewithanexternaldevicesthatcanbenetfromtheprocesseddata.SuchdevicesincludetheOlexcha

Page 191 - Cableidentication

InterfacesandintegrationRelatedtopics•RJ45Ethernet,straightonpage49•RJ45Ethernet,crossoveronpage50HowtosetuptheSimradITITrawlsysteminterfaceCommunicat

Page 192

InstallationmanualVTGCourseoverground&groundspeed...166Proprietarytelegramsandformats...

Page 193

SimradES705IntheSelectInputsdialog,locatetheITIontheleftside,andclickthe[>]buttontoconnectit.•ITI:ThissettingallowsyoutocommunicatewiththeSimradITI

Page 194

Interfacesandintegration5Ensurethatthelengthofthecabledoesnotexceedapproximately50meters.Ifalongercableisrequired,youmayneedtousebufferampliersonthes

Page 195

SimradES70HowtosetupthesonarsysteminterfaceThecurrentdepthfromadenedtransceiverchannelcanbesentoutonaseriallinetoasonarsystem.Youcanonlyusetheseriall

Page 196

InterfacesandintegrationSupportedtelegramformatsforheading:•HDGHeading,deviationandvariationonpage164•HDTHeading,trueonpage165•HDMHeading,magneticonpa

Page 197

SimradES70IfyouchooseAuto,theES70willautomaticallychooseamongtheincominginformationaccordingtoapredenedprioritylist.dIfapplicable,denetheTalkerID.4C

Page 198

Interfacesandintegration5IntheSelectInputsdialog,locatetheAMLontheleftside,andclickthe[>]buttontoconnectit.Thissettingallowsyoutocommunicatewiththe

Page 199

SimradES70Setupprocedure1ClicktheSetupiconundertheMainmenutoopentheSetupsub-menu.2ClickDepthOutputtoopentheDepthOutputdialog.3Selectwhichporttouse.4Fo

Page 200 - 2010KongsbergMaritimeAS

Interfacesandintegration2ClickAnnotationstoopentheAnnotationsdialog.3ClickPortsoselectcommunicationport.4ClickSetupsodenethecommunicationparameters.5

Page 201

SimradES70MastersystemOntheES70computer,RTS(pin7)goeslogical“low”(typically+10Vdc)approximately2to3mspriortotransmitting,andreturnstological“high”(typ

Page 202

InterfacesandintegrationConnectthegroundwiretooneoftheGroundpins(18-22).SlavesystemIfanexternalsystemisusedtoprovidethetransmittrigger,thetriggersigna