Simrad SP 270
1", "' Set\tn'
fldistingllowering switch S302 to HOIST position
and check that the
hoisting contactor K301 is activated
when pressing the hand crank safety switch
S303.
Set the hoistingllowering switch
S302 to LOWER
position
, and check that the lowering contactor K302 is
activated when pressing the hand crank
safety switch
S303.
Set the hoistingllowering switch S302 to
STOP position.
Replace the hand
crank to its storage position in the
motor control unit.
Activate the hoisting
contactor K30 1 by
setting the
hoistingllowering switch S302 to HOIST position
, and
check if the contactor is deactivated when pressing the
upper limit switch S304 upwards (see
figure 3).
Activate the lowering
contactor K302 by setting the
hoistingllowering switch S302 to
LOWER position
, and
check if the contactor is deactivated when pressing the
lower limit switch S305 downwards.
Set the hoistingllowering switch S302 to
STOP position.
Reinsert the three-phase mains fuses for the Hull Unit
on the ship
s mains switchboard.
Measure the three-phase voltage on the
terminals of the
motor overload switch S301 in the motor control unit.
Write measured three-
phase voltage here:.......................
The hoist/lower motor is
preconnected for 380V/440V
three-phase. If the measured three-
phase voltage is
230v, the motor has to be reconnected. Remove the cover
for the mains connection on the motor
, and refer to figure
4 to link the
motor connections to correspond to the
measured voltage.
Adjust the release current of the motor
overload switch
S301 according to the three-
phase voltage:
230V: 3.4 A
380/440V: 2.
4 (minimum)