Simrad AP70 Installation Manual Page 67

  • Download
  • Add to my manuals
  • Print
  • Page
    / 80
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 66
| 65
Speci cations | AP70/AP80 Installation manual
AP70 and AP80 Control units
AP70 AP80
DISPLAY
Size 5 in\127 mm
Resolution (HxW) 480x480
Type 16-bit color TFT
Antifog bonded
Best viewing direction any direction
Backlight Cold Cathode Fluorescent Lamp (CCFL)
NETWORKING
CAN bus x
USB N/A x
Ethernet for sw update
POWER
Local supply 12/24 V DC +30-10%
Consumption local supply 0.7/0.4 A at 12 V DC 0.4/0.3 A at 24 V DC
backlight full/off "
NMEA 2000 Load Equivalent
number (50 mA)
1
INTERFACE External alarm/Active unit output max 100 mA, 4.5 A short
circuit limit
External Take CMD input, contact current max 8 mA
ENVIRONMENT
Temperature, operation -30°C to +55°C (-22°F to 131°F)
Temperature, storage -25°C to +70°C (-13°F to 158°F)
Protection IPx4 IPx6
MECHANICAL
Weight 1,2 kg (2.7 lbs) 1,4 kg (3.1 lbs)
Size Refer “Drawings” on page 74
Mounting Panel (fl ush) or optional bracket
Material Plastic Epoxy coated seawater
resistant aluminium back
cover, plastic front bezel
Color Black and grey
Cable inlet 1 Power/alarm, 1 Micro-C con.