Operationalprocedures
12Checkthedataowontheinputcommunicationline.
Inordertomonitorthisdataow,theperipheralsystemmustbeactiveand
transmittinginformationtotheES70.
13Ifthedataowisoperational,closealldialogs.
Settinguptheinputfromananaloguetemperaturesensor
ThisprocedureexplainshowtosetuptheES70toreceivetemperatureinformation
throughtheanalogueinputontheGeneralPurposeTransceiver(GPT).
Ifmorethanonetransceiverisusedbytheechosoundersystem,asingletemperature
sensorisonlyconnectedtoonlyoneofthem.Ifyouhavemorethanonesensorand
severaltransceivers,youcanconnectonesensortoeachtransceiver,andthen–inthe
Temperaturesensordialog–selectwhichonetoread.
Therststep(withsub-steps)inthisprocedureexplainshowtodothephysicalcabling
usingaseriallineoranEthernetconnection.Theremainingstepsdescribehowtosetup
theinterfaceintheES70software.
1ConnectthetemperaturesensortotheES70system.
aOntheES70GeneralPurposeTransceiver,connectthepositivesignalfromthe
sensortopin4ontheAuxiliaryconnectorontheGeneralPurposeTransceiver.
bConnectthegroundsignalfromthetemperaturesensortopin17onthe
Auxiliaryconnector.
2OntheES70,accesstheInstallmenu,andopentheTemperaturesensordialog.
3ForSourceselection,selectAnaloginput.
4Selectwhichtransceiveryouhaveconnectedthetemperaturesensorto.
Whenthesensorisoperational,youwillbeabletofollowthetemperaturereadings
inthedialog.
Settingupthedepthoutputtoaperipheralsystem
Thisprocedureexplainshowtosetupaseriallinetoexportthisinformationtoa
peripheralsystem.
TheES70willoutputdepthinformationonseveraldifferentformats.
Thefollowingtelegramsaresupported:
→DBSDepthbelowsurfaceonpage266
→DBTDepthbelowtransduceronpage266
→DPTDepthonpage267
→SimradEK500Depthtelegramonpage273
→Atlasdepthtelegramonpage281
→PSIMDHBBottomhardnessandbiomassonpage278
338106/C
103
Comments to this Manuals