Simrad AP50 User Manual Page 91

  • Download
  • Add to my manuals
  • Print
  • Page
    / 188
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 90
Installation
20221032B 89
4.10 Drive Unit Installation
The relation between drive units, drive unit voltage, input
voltage, drive output, and interfacing to steering gear are shown
in Table 4-2 and Table 4-3. The AP50 system detects whether a
reversible motor or a solenoid is connected and outputs the
correct drive signal automatically.
Refer to the connecting diagrams for the different drive units on
pages 91 through 93.
Installation instructions for the drive units are found in the
manuals for the individual units.
The maximum drive current capabilities of the J50 and J50-40
Junction Units are different. Use the table below as a reference
and observe the notes.
HYDRAULIC PUMPS
RAM CAPACITY
MODEL MOTOR
VOLTS
JUNCTION
UNIT
MIN.
cm
3
(cu. in.)
MAX.
cm
3
(cu. in.)
FLOW
RATE AT 10
bar
cm
3
/min.
(cu. in./min.)
MAX.
PRES-
SURE
bar
PWR.
CONSUMP-
TION
RPU80 12 J50 80 (4.9) 250 (15.2) 800 (49) 50 2,5-6 A
RPU160 12 J50 160 (9.8) 550 (33.5) 1600 (98) 60 3-10 A
RPU200 24 J50 190 (11.6) 670 (40.8) 2000 (122) 80 3-10 A
RPU300 12 J50-40 290 (17.7) 960 (58.5) 3000 (183) 60 5-25 A
RPU300 24 J50 290 (17.7) 960 (58.5) 3000 (183) 60 2,5-12 A
RPU3 24 J50 370 (22.4) 1700 (103) 3800/5000
(232/305)
40 7-22 A
RPU1 12 J50 140 (8.5) 600 (36.6) 1400/2000
(120/185)
40 7-22 A
Steering Gear Interface: Hydraulic Plumbing
Table 4-2 Hydraulic Pumps
Page view 90
1 2 ... 86 87 88 89 90 91 92 93 94 95 96 ... 187 188

Comments to this Manuals

No comments