Simrad GC80/GC85 Compact Gyro Compass
104 20221511 / C
Alarm
code
Alarm content
Detailed
code
Possible cause
E-F
MAG/EHS data
abnormal
33 EHS data abnormal. (timeout is 17 sec.)
E-L
EXT. sensor
communication off
30
When EXT. sensor system is stopped or serial signal
from EXT. sensor is cut. (timeout is 15 sec.)
E-n
EXT. sensor data
abnormal
31 EXT. sensor data abnormal.(timeout is 17 sec.)
E-P
LOG(serial)
communication off
28
When LOG (serial) system is stopped or serial signal
from LOG (serial) is cut. (timeout is 15 sec.)
E-U
LOG(serial) data
abnormal
29 LOG (serial) data abnormal.(timeout is 17 sec.)
E-r E5V is lost 34 E5V (power supply of serial signal) is lost.
E-G
Master bearing is
abnormal
35
When compensation of the bearing by the encorder
signal is not completed.
E-u *1
LOG(contact)
data abnormal
37 LOG (contact) is abnormal.
*1: This alarm code is not displayed to customer.