Technicalspecications
Operationalperformance
Coverage
Horizontalplane:±30degrees
Verticalplane:0to45degrees
Figure55Frequency/Sectorplot
Motioncompensation
Rollcompensation:±10º
Sidelobelevel
-35dBhorizontal(alongship)
-25dBvertical
Transmitandreceive
Sourcelevel:225dB
Receiverdynamicrange:150dB(instantaneous)
Individualtransmitterchannels:800
Individualreceiverchannels:800
Pingrate:2Hz
Samplerates
Outputsamplerate:62,5kHzcomplexsampling(beforedecimation)
Outputsamplelength:Minimum1,2cm
331549/B