SimradMS70
Figure20MultibeamOperatorStation
Operatorstation
installation
requirements
InstallationoftheMS70Multibeam
OperatorStationunitsmustbe
performedbyqualiedandtrained
personnel.Observethefollowing
generalguidelinesforinstallation.
Thesafenavigationofthevessel.
The“Compasssafedistance”for
eachindividualunit.
Ergonomicallycorrectoperating
andviewingheights.
Maximumallowablecabledistancesbetweenthevariousunits.
Theinstallationareasaredry,wellventilatedandfreeofexcessivedustandvibration.
Easyaccesstothecableconnectionsonthebackoftheequipmentisprovided.
Enoughextracableisallowedtofacilitatemaintenanceandservicebynothaving
todisconnectthecables.
Operatorstationcomputerinstallation
ThissectiondescribestheinstallationoftheMS70MultibeamOperatorStationcomputer.
Preparations
Provideamplespacearoundthecomputer.Thisisnecessarytoreachandusethefront
andrearmountedUSBconnectors,andtheCD/DVDplayer.Itisalsoimportantto
allowforeasyaccesstoallthecables,andtoprovideforinspection,maintenanceand
partsreplacement.
Makesurethatthecomputercanbefullyopenedforunobstructedaccesstoitsinternal
parts.
Thecomputercanbeinstalledinsideaconsole,inacabinetor19”rack,oronadesk.
Makesurethatadequateventilationisavailabletoavoidoverheating.
Thecompasssafedistancemustbeallowedforwhenplanningthelocationoftheunit.
Ensurethattheinstallationallowsforthephysicalmovementsandforcesnormally
experiencedonavessel.
Ensurethatenoughspaceisprovidedformaintenancework.
60