Cablelayoutandinterconnections
Readthisrst!
Detailedinformationaboutcablespecications,terminationandconnectorsareprovided.
AllcablesareprovidedbySimradunlessotherwisespecied.Inordertoprovidefor
maintenanceandtoallowforvibration,makesurethatsomeslackisprovidedforall
cables.
Adetaileddrawingforeachcableisprovided.Eachdrawingprovidesadditional
specications,andmay,whenapplicable,include:
Requiredminimumspecications
Connectionsateachend(includingreferencetothecorresponding:systemunit,
terminalboardidenticationandplug/sockettobeused)
Correspondingterminations
Numberofcores
Cablesfallintotwocategories.
Systemcables:ThesecablesaresuppliedbyKongsbergMaritime.
Shipyardcables:Thesecablesmustbeprovidedbytheshipyardperformingthe
installation,ortheshipowner.Itisveryimportantthatthecablesusedmeetthe
minimumspecicationsprovidedinthismanual.
KongsbergMaritimeacceptsnoresponsibilityfordamagetothesystemorreduced
operationalperformancecausedbyimproperwiring.
Formoreinformation,seethegenericcablerequirements.
Basiccablerequirementsonpage200
Note
BeforeyouperformtheMS70cabling,ensurethatthemainscircuitbreakerforthe
systemisswitchedoff.
Note
Allelectronicinstallationsandcorrespondingwiringmustbeinaccordancewiththe
vessel’ snationalregistryandcorrespondingmaritimeauthorityand/orclassication
society.Ifnosuchguidelinesexist,werecommendthatDetNorskeVeritas(DNV)Report
No.80-P008«GuidelinesforInstallationandProposalforTestofEquipment»isusedas
aguide.ObserveBasiccablerequirementsonpage200.