Simrad TRANSDUCER - INSTALLATION GENERIC REV H Installation Manual Page 27

  • Download
  • Add to my manuals
  • Print
  • Page
    / 212
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 26
Installationplanning
Ifthevesselhullhasabulbousbow,thismaywellbeagoodtransducerlocation,but
alsoheremustbetakenintoconsiderationtheowpatternoftheaeratedwater.Often
theforemostpartofthebulbispreferable.
Figure6Recommendedlocationofthetransducer
onabulboushull
AThruster
BTransducerlocation
Sonarroomrequirements
The“sonarroom”isthecompartmentinwhichtheTransceiverUnitandthePower
SupplyUnitsareinstalled.
ObservetheseminimumrequirementstoobtainsuitableworkingconditionsforMS70
installation,useandmaintenance.
Sizeandaccess
Awelldesignedsonarroomreducestheriskofcorrosionandsimpliesmaintenance
increasingsystemreliability.
Thesonarroommustbedimensionedtohousealltherelevantcabinetsthatcomprise
theSimradMS70.
Thephysicaldistancebetweenthetransmittersandthetransducerislimiteddue
tothelengthofthetransducercables.
Thesonarroommustnotbeunnecessarilyobstructedbygirders,pipesetc.which
mightcauseinstallationproblemsorimpedemaintenance.
Thesonarroommustbeaccessibleunderallconditionsatseaorataberth.
Alldoorsorhatchesmustbedesignedsothattheequipmentcanberemovedwithout
beingdisassembled.
Heating
Thesonarroommustbeequippedwithheater,dimensionedtomaintaintheequipment
withinitsenvironmentaltolerances(atleast1000W),installedclosetothedeck.Heating
isalsoaneffectivemethodforreducinghumidity.
331549/B