Installation
20220760L 75
Power connection
There is no power cable supplied for the Transceiver. Use a
cable with minimum wire gauge of 1.5mm
2
(AWG14). The outer
diameter should be 10 mm (0,4”) to ensure a tight fit through the
gasket.
Connect the Power cable to TB1 on the IS15 Transceiver PCB
and the other end to a circuit breaker.
The connection is polarity protected and monitored by a green
LED. If a red LED is lit on the PCB, swap the supply wires (see
Figure 6-16).
6.10 IS15 Instruments as NMEA repeaters
Figure 6-20, Figure 6-21 and Figure 6-22 are examples of how
IS15 instruments can be used as NMEA repeaters. Depth, speed
and temperature can be displayed when connected to a Simrad
CEXX Chart plotter/Echo sounder or CAXX Multifunction
radar. Any preferred combination of instruments can be used, the
IS15 Combi for example is an excellent display also for wind
data presentation.
Installing the Roblink Power Cable
The configuration in Figure 6-20 is limited to a total of 3
instruments and a Roblink Power Cable (P/N 22093587) is
required to enhance the Roblink signals. Connect the cable to a
circuit breaker. Extend the cable if necessary using a wire gauge
of 0,75 mm
2
(AWG18).
Notes !
1. If an IS15 Wind Transducer is connected to the IS15
instruments when using this configuration, it must
be
plugged into connector no. 2 (Roblink) on instrument head
no. 3. Refer to note 2 for NMEA connection.
2. If only a single instrument is installed (Figure 6-22) there is
no need for the Roblink Power Cable. Simply cut the 0,3 m
(1’) cable that comes with the instrument in two and extend
the halves to the 12V supply and the NMEA source
respectively using twisted pair cable. – Also refer to
instructions for Roblink turn-off (paragraphs 7.3 or 7.13.)