Installation
20220760L 81
Total length of Roblink cables
The IS15 Expander can drive a total of 8 instrument heads. They
can be connected to J1 (port 1) and J2/J4/J5 (port 2) of the
Expander with maximum 7 instrument heads to one port. The
total length of the interconnecting Roblink cables should not
exceed 30 m from each port as shown in Figure 6-25.
Note ! The length of the masthead cables shall not be included in the
above.
SIMRA D
INSTR. #1
SIMRA D
IS15
EXPANDER
INSTR. #7
30m (99')
Max 7 instrument heads in one chain
Total length of all Roblink cables, max. 30 m (99')
SIMRAD