Voltage output: ............................................................................Operating voltage/2 ±9V
Frequency output:.................................................................3400Hz (midships reference)
Port: +20Hz/degree, Stbd: –20Hz/degree
Capacity: .........................................................................................5 indicators in parallel
Rudder angle: ............................................................ ±45 ° (Changeable to 60, 70 or 90°)
Limit switches: .....................................Two sets, individual adjustable from ±5 to ±160°
120 (4.8")
40 (1.6")
75 (3")
80 (3.15")
Ø12 (0.47")
185 (7.3")
150 (5.9")
240 (9.5")
160 (6.3")
Ø
8
(
0
.
3
")
Figure 6-9 RF14XU Rudder Feedback Unit