Software Set-up Procedure
20222469 / B 59
Set-up item
(abbrev. name)
Equipment
connected
(name)
Connected to terminal
(use one available from list)
Assign hardware
port to set-up item
(* = default setting)
GYRO2 Not connected – – – – *
Connection to Robnet ROBNET **
J50, Power PCB NMEA I/P RX2+,RX2– J50-2
NI300X, NMEA port #1 NI300-1
NI300X, NMEA port #2 NI300-2
NI300X, NMEA port #3 NI300-3
NI300X, NMEA port #4 NI300-4
GI51, Gyro terminal GI-sync
GI51, Gyro terminal GI-step
GI51, Gyro terminal GI-0183
GI51, Gyro terminal GI-prop
THD1 Not connected – – – – *
Connection to Robnet ROBNET **
J50, Power PCB NMEA I/P RX2+,RX2– J50-2
NI300X, NMEA port #1 NI300-1
NI300X, NMEA port #2 NI300-2
NI300X, NMEA port #3 NI300-3
NI300X, NMEA port #4 NI300-4
THD2 Not connected – – – – *
Connection to Robnet ROBNET**
J50, Power PCB NMEA I/P RX2+,RX2– J50-2
NI300X, NMEA port #1 NI300-1
NI300X, NMEA port #2 NI300-2
NI300X, NMEA port #3 NI300-3
NI300X, NMEA port #4 NI300-4
MAGN1 Not connected – – – – *
CD100A + CDI35 Junction unit: HS+, HS– J50-HS
J50, Power PCB NMEA I/P RX2+,RX2– J50-2
NI300X, NMEA port #1 NI300-1
NI300X, NMEA port #2 NI300-2
NI300X, NMEA port #3 NI300-3
NI300X, NMEA port #4 NI300-4
CD100A CI300X Magnetic Compass terminal CI300X
MAGN2 Not connected – – – – *
CD100A + CDI35 Junction unit: HS+, HS– J50-HS
J50, Power PCB NMEA I/P RX2+,RX2– J50-2
NI300X, NMEA port #1 NI300-1
NI300X, NMEA port #2 NI300-2
NI300X, NMEA port #3 NI300-3
NI300X, NMEA port #4 NI300-4
CD100A CI300X Magnetic Compass terminal CI300X