Simrad SH90 - PRODUCT DESCRIPTION REV A Specifications Page 92

  • Download
  • Add to my manuals
  • Print
  • Page
    / 122
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 91
IS15 General Manual
90 20220760L
Note ! When an instrument is replaced it is important that a Master
Reset has been made on the new one before it is connected to the
system. Refer to section 9.5 Local Master Reset on page 118.
7.2 Installation and Calibration Menu
After installation, certain functions in the system should be
calibrated to take into account the physical position and type of
transducers installed. Furthermore the preferred display units
should be selected.
The installation screens of the IS15 digital instruments are
arranged in a ‘table’ as below. It consists of a number of menu
groups, each group being a logical collection of screens. Access
to the menu and the individual screens are described below.
2 sec.
Screen
Group
Screen 1
Screen 2
Screen 3
Screen 4
Screen 5
Screen 6
Screen 7
Screen 8
Group 1
General
Illuminat-
ion bank
LCD
Contrast
Shop mode
(on/off)
NMEA
communica
tion In/out
Roblink
com. & id
(on/off)
Roblink
test *
Com.
(municat-
ion) Reset
Master
reset
Group 2
Depth
Depth unit Depth
offset
Depth
source *
Group 3
Boat speed
Speed unit Log
calibration
factor
Log
calibration
SOG
Log
calibration
Distance
Log
source *
Group 4
Temperature
Tempera-
ture unit
Group 5
Wind
Wind
Speed unit
Wind angle
offset
(Automatic)
Wind angle
offset
(Manual)
Wind
source *
Group 6
Navigation
Distance
unit
Pos.
source*
Nav.
Source *
Group 7
Compass
Compass
calibration
Heading
offset
Bearing
unit
Heading
source *
Group 8
Rudder *
Rudder
angle
offset
Rudder
angle
source
Group 9
Expander **
Local
Master
Reset
Software
Version
* IS15 Combi only
** IS15 Combi only. Applies with an IS15 Expander in the system.
Page view 91