Simrad AP50 Installation Manual Page 110

  • Download
  • Add to my manuals
  • Print
  • Page
    / 134
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 109
Technical Specifications
20222469 / B 101
Cable:.................................................................15 m (49 ft.) single twisted pair, shielded
Automatic Performance:
Calibration: ............................................. Automatically activated by control head
Repeatability:.................................................................................................± 0.5°
Accuracy:....... ± 1,0° after calibration (not including errors from course detector)
6.7 CD100A Course Detector
Dimensions:.................................................................................................See Figure 6-6
Weight: .............................................................................0.3 kg (0.7 lbs.) including cable
Environmental Protection:...........................................................................................IP56
Temperature range:
Operation: ..............................................................–25 to +55°C (–13 to + 130°F)
Storage:................................................................... –30 to +70°C (–22 to +158°F)
Mounting: ............................................Attached to compass by screw or by tripod holder
Cable length:.........................................................................7 m (23 ft.), no plug included
6.8 CD109 Course Detector
Dimensions:.................................................................................................See Figure 6-6
Weight: .............................................................................0.3 kg (0.7 lbs.) including cable
Environmental Protection:...........................................................................................IP56
Temperature range:
Operation: ..............................................................–25 to +55°C (–13 to + 130°F)
Storage:................................................................... –30 to +70°C (–22 to +158°F)
Mounting: ............................................Attached to compass by screw or by tripod holder
Cable length:..............................................................................1 m (3 ft.) with AMP plug
120°
120°
120°
min/max. 80-100mm (3.2-4.3")
Ø
6
0
(
2
.
4
"
)
35 (1.4")
Figure 6-6 CD100A/CD109 Course Detector Dimensions