Installation
20222469 / B 27
Use the following table as a guideline.
Number of Robnet units Maximum cable length in m (feet)
1 390 (1270’)
2 195 (640’)
3 130 (425’)
4 95 (310’)
5 75 (245’)
6 65 (210’)
7 55 (180’)
8 50 (165’)
9 45 (150’)
10 40 (130’)
If the total length exceeds the recommended length, please
contact your Simrad distributor on how to arrange the system to
minimize the voltage drop.
Examples of interconnecting Robnet units:
CONTROL
UNIT
JUNCTION
UNIT
NI300X
CONTROL
UNIT
CONTROL
UNIT
JUNCTION
UNIT
NI300X
CONTROL
UNIT
Figure 2-21 Interconnecting Robnet Units
All connectors are crimp-type and can be easily disassembled if
desired for ease of installation (see
Figure 2-22).
HOW TO REMOVE PINS:
Insert tool in slot
Pull the wire